Summary of Impact:
Starting at approximately 17:40 UTC on November 11, 2026, Qlik Talend Cloud customers in the AWS Europe (Frankfurt) region experienced elevated failure rates when starting flows and tasks in the Talend Management Console. Some scheduled runs did not start or were rejected, and some Remote Engines were temporarily reported as unavailable. Service was restored by 19:17 UTC, but the issue recurred in intermittent waves, with the last customer impact observed at approximately 08:00 UTC on November 12, 2026. A subset of customers was affected.
Root Cause:
A background encryption key migration for one account with an exceptionally large number of keys was repeatedly retried by the platform. Each attempt tried to process all of the account’s keys at once, which exhausted the memory of the encryption service. While in this state, the service remained available but could not respond correctly, so dependent components could not authenticate and Remote Engines lost their connections.
The migration could not complete and had no retry limit, so the cycle repeated every 15 minutes until the migration was allowed to finish.
Resolution and Remediation:
Engineers restarted the affected components and increased the memory and capacity of the encryption service, which restored service. The migration then completed at 15:02 UTC on November 12, ending the recurring failures. All further key migrations have been paused until the fixes below are in place.
Qlik Engineering will complete the following actions with the goal of preventing this issue from recurring:
We apologize for any inconvenience this disruption may have caused to your operations.